Specialists in Draught Soft Drinks, Commercial Refrigeration & Air Conditioning Sales, Service & Breakdown

Tel:

01455 233228

Email:

info@empireuk.com

Fault Finder

Symptom Fault Action
Carbonation
Flat Drinks CO2 Cylinder Valve Closed Open The CO2 Cylinder Valve
CO2 Cylinder Empty Change The CO2 Cylinder, Pull Off 4 Pints Of Soda Water
CO2 Pressure Low Change The CO2 Cylinder
Drink Too Warm Clean Or Clear The Refrigeration Grills/Switch The Unit On
Excessive Foaming Dirty Nozzle/Diffuser Clean The Dispenser Nozzle/Diffuser
Drink Too Warm Clean Or Clear The Refrigeration Grills/Switch The Unit On
Large CO2 Consumption Empty Bag In Box Replace The Empty Bag-In-Box With A Fresh Bag-In-Box Of The Same Flavour. If No Change Of Box Is Available Then Submerge Bag-In-Box Connector Into Water
Sealing Washer Link Check The Sealing Washer Is In Place
Taste
Too Weak/Strong CO2 Pressure Low Change The CO2 Cylinder
Dispensed Valve Out Of Adjustment Call Us On: 01455 233228
Off Taste Dirty Nozzle Clean The Dispenser Nozzle/Diffuser
Wrong Flavour Connected Connect Syrup Line To Correct Flavour & Open Valve Until Rectified
Dirty Product Line Call Us On: 01455 233228
Flavour Strength
No Syrup Empty Bag In Box Replace Empty Bag In Box With A Fresh Bag-In-Box Of The Same Flavour
Line Obstruction Free Lines Of Any Restrictions
Faulty Change-Over (Where Fitted) Manually Switch Change-Over Valve To Full Bag In Box
CO2 Cylinder Valve Closed Open The CO2 Cylinder Valve
CO2 Cylinder Empty Change The CO2 Cylinder
Faulty Syrup Pump Call Us On: 01455 233228
No Carbonated Water Water Off Open Mains Water Stop Cock
CO2 Cylinder Valve Closed Open The CO2 Cylinder Valve
Reset Button Trapped Press Reset Button Or Unplug At Socket For 3 Seconds
Temperature
Drink Too Warm Refrigeration Unit Not Working Check Main Power Supply, Switch On Power For Refrigeration Unit
Insufficient Airflow Through Condenser (Dirty Grill) Clean Cooler/Condenser Grill
Grill Obstruction Remove Any Objects Blocking Air Into Or Out Of The Refrigeration Unit